Chilled Water Based In-Row Front Cooler Unit

Chilled Water Based In-Row Front Cooler Unit

Ideal solution for hot and cold aisle applications!

OVERVIEW
OPTIONS
TECHNICAL DOCUMENTS

CoolAer’s Chilled Water Based In-row Front Coolers were designed to work specifically in cold and hot aisle containment applications in dense data center environments, without the need for a raised floor. Their modular engineering gives you the ability to meet the most demanding data center needs, while also precisely controlling your capital expenditure. You can invest in the amount of cooling you need now and, as your needs grow, add more units to your system for increased cooling.

CoolAer has designed a number of chilled-water based front coolers to meet a variety of needs in data center environments. They range in size from 300-600mm wide and 1000-1200mm deep, and are 2000mm tall. Based on the model, they can achieve cooling capacities of up to 30 or 60kW.

Because chilled-water based systems are part of a chiller system, they don’t rely on condensers to cool their refrigerant. Instead, water chilled to 14°C is brought through a closed loop to the air handling unit’s cooling fans.

The variable-speed fans are temperature controlled to automatically deliver the right amount of cooling and adjust for spikes and gaps in server usage. Their motors are a brushless (electronically commutated) design for increased power, speed, control, and reliability, and reduced maintenance.

Our design is further improved to ease the cycles of maintenance and repair, by making our cooling fans hot swappable. If a problem occurs and a fan needs to be replaced or repaired, operations can continue without impacting operations or customer experience.

The system can be monitored and controlled with an optional SNMP (Simple Network Management Protocol) card. This allows administrators to monitor how well the system is working holistically, and to better identify any possible hotspots, leaks in the hot/cold aisle containment, under-used servers, or other issues.

Highlights

-  Cooling capacity range from 30kW to 60kW.

-  Remote access and control

-  Teamwork of up to eight devices

-  Easily intervenable electrical panel with skid board structure

-  Easy changeable coarse filter without equipment. Washable and cleanable.

-  EC intelligent radial fan

-  Detachable fan structure

-  Ability to change the fan during device operation

-  SHR: 1.00

-  Different operation options according to pressure difference and temperature principle

-  Suitable for raised flooring, lowered ceiling and air duct systems

-  Flexible installation

-  Humidity control option

-  External DC input to keep automation active in case of power failure

-  Fire alarm input

-  Remote control option from a different device

-  Ability to store alarm history up to 100 logs

-  7" Touch Screen
-  BACnet/IP
-  Steam Humidifier
-  Electric Heater
-  Energy Analyzer
-  Modbus TCP
-  Automatic Transfer Switch
-  SNMP Module
-  Ultra Capacitor
-  Web Interface